Back to map dashboardDistribution Pole Fiber Continuity
VT-UNKNOWN171595-FD-01 synthetic telecom fiber / VT-UNKNOWN171595-FD-01 synthetic telecom fiber
!Synthetic distribution continuity only. Do not use for operations, dispatch, restoration, SCADA, protection, or CEII analysis.
Utility ownerVillage of Morrisville Water & Light Department
StateVT
Fiber routeDIST-FIBER-01178
Fiber count24F
Display poles11
Scale model2,200
Splice points3
Slack loops4
Slack storage916 ft
Assignments9
Route miles3.93
Estimated loss2.20 dB
Continuitycomplete synthetic
Statusin service synthetic
Street-Path Continuity
VT-UNKNOWN171595-FD-01SOUTH-GORHAM-STR-0103 96F Patch Panel to DIST-POLE-0011824
- Route
- DIST-FIBER-01178
- Street path
- SYN-STREET-01178
- Fiber
- 24F
- Poles
- 11
- Scale
- 2,200
- Loss
- 2.20 dB
- 1VT-UNKNOWN171595-FD-01-P00001riser
- 2VT-UNKNOWN171595-FD-01-P00002distribution backbone
- 3VT-UNKNOWN171595-FD-01-P00003distribution backbone
- 6VT-UNKNOWN171595-FD-01-P00006distribution backbone
- 9VT-UNKNOWN171595-FD-01-P00009distribution backbone
- 10VT-UNKNOWN171595-FD-01-P00010fiber lateral
- 11VT-UNKNOWN171595-FD-01-P00011distribution backbone
Services Carried
Telecom Backhaul on VT-UNKNOWN171595-FD-01Telecom Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.29 dB
Distribution Automation on VT-UNKNOWN171595-FD-01Distribution Automation synthetic distribution telecom service familyactive synthetichighsynthetic2 strands1.29 dB
AMI Backhaul on VT-UNKNOWN171595-FD-01AMI Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.48 dB
Relay Engineering Access on VT-UNKNOWN171595-FD-01Relay Engineering Access synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.48 dB
Voice Operations on VT-UNKNOWN171595-FD-01Voice Operations synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.57 dB
PMU Backhaul on VT-UNKNOWN171595-FD-01PMU Backhaul synthetic distribution telecom service familyactive synthetichighsynthetic2 strands1.67 dB
Protection Pilot on VT-UNKNOWN171595-FD-01Protection Pilot synthetic distribution telecom service familyactive syntheticcriticalsynthetic2 strands1.87 dB
Voltage Regulator Backhaul on VT-UNKNOWN171595-FD-01Voltage Regulator Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.96 dB
Wireless Backhaul Handoff on VT-UNKNOWN171595-FD-01Wireless Backhaul Handoff synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.87 dB
Splice and Slack Continuity
| Type | Node | Pole | Route | Slack | Status |
|---|
| riser terminal | VT-UNKNOWN171595-FD-01-P00001 riser terminal DIST-SPLICE-003706 | VT-UNKNOWN171595-FD-01-P00001 | DIST-FIBER-01178 | 282 ft | in_service_synthetic |
| inline splice | VT-UNKNOWN171595-FD-01-P00006 inline splice DIST-SPLICE-003707 | VT-UNKNOWN171595-FD-01-P00006 | DIST-FIBER-01178 | 166 ft | in_service_synthetic |
| riser terminal | VT-UNKNOWN171595-FD-01-P00011 riser terminal DIST-SPLICE-003708 | VT-UNKNOWN171595-FD-01-P00011 | DIST-FIBER-01178 | 300 ft | in_service_synthetic |
| riser storage | VT-UNKNOWN171595-FD-01-P00001 splice slack DIST-SLACK-004640 | VT-UNKNOWN171595-FD-01-P00001 | DIST-FIBER-01178 | 282 ft | in_service_synthetic |
| splice slack | VT-UNKNOWN171595-FD-01-P00006 splice slack DIST-SLACK-004641 | VT-UNKNOWN171595-FD-01-P00006 | DIST-FIBER-01178 | 166 ft | in_service_synthetic |
| riser storage | VT-UNKNOWN171595-FD-01-P00011 splice slack DIST-SLACK-004642 | VT-UNKNOWN171595-FD-01-P00011 | DIST-FIBER-01178 | 300 ft | in_service_synthetic |
| maintenance loop | VT-UNKNOWN171595-FD-01-P00005 maintenance loop DIST-SLACK-004643 | VT-UNKNOWN171595-FD-01-P00005 | DIST-FIBER-01178 | 168 ft | in_service_synthetic |