Back to map dashboardDistribution Pole Fiber Continuity
RI-WARREN-FD-01 synthetic telecom fiber / RI-WARREN-FD-01 synthetic telecom fiber
!Synthetic distribution continuity only. Do not use for operations, dispatch, restoration, SCADA, protection, or CEII analysis.
Utility ownerRhode Island Energy
StateRI
Fiber routeDIST-FIBER-01092
Fiber count12F
Display poles10
Scale model2,000
Splice points2
Slack loops3
Slack storage700 ft
Assignments4
Route miles4.80
Estimated loss2.35 dB
Continuitycomplete synthetic
Statusneeds field verification
Street-Path Continuity
RI-WARREN-FD-01UNKNOWN125030-STR-0020 72F Patch Panel to DIST-POLE-0010920
- Route
- DIST-FIBER-01092
- Street path
- SYN-STREET-01092
- Fiber
- 12F
- Poles
- 10
- Scale
- 2,000
- Loss
- 2.35 dB
- 1RI-WARREN-FD-01-P00001riser
- 2RI-WARREN-FD-01-P00002distribution backbone
- 3RI-WARREN-FD-01-P00003distribution backbone
- 4RI-WARREN-FD-01-P00004distribution backbone
- 5RI-WARREN-FD-01-P00005distribution backbone
- 6RI-WARREN-FD-01-P00006distribution backbone
- 7RI-WARREN-FD-01-P00007distribution backbone
- 8RI-WARREN-FD-01-P00008distribution backbone
- 9RI-WARREN-FD-01-P00009distribution backbone
- 10RI-WARREN-FD-01-P00010fiber lateral
Services Carried
Telecom Backhaul on RI-WARREN-FD-01Telecom Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.38 dB
Distribution Automation on RI-WARREN-FD-01Distribution Automation synthetic distribution telecom service familyactive synthetichighsynthetic2 strands1.47 dB
Relay Engineering Access on RI-WARREN-FD-01Relay Engineering Access synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.74 dB
PTP Timing Extension on RI-WARREN-FD-01PTP Timing Extension synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.98 dB
Splice and Slack Continuity
| Type | Node | Pole | Route | Slack | Status |
|---|
| riser terminal | RI-WARREN-FD-01-P00001 riser terminal DIST-SPLICE-003426 | RI-WARREN-FD-01-P00001 | DIST-FIBER-01092 | 222 ft | needs_field_verification |
| riser terminal | RI-WARREN-FD-01-P00010 riser terminal DIST-SPLICE-003427 | RI-WARREN-FD-01-P00010 | DIST-FIBER-01092 | 239 ft | needs_field_verification |
| riser storage | RI-WARREN-FD-01-P00001 splice slack DIST-SLACK-004284 | RI-WARREN-FD-01-P00001 | DIST-FIBER-01092 | 222 ft | needs_field_verification |
| riser storage | RI-WARREN-FD-01-P00010 splice slack DIST-SLACK-004285 | RI-WARREN-FD-01-P00010 | DIST-FIBER-01092 | 239 ft | needs_field_verification |
| maintenance loop | RI-WARREN-FD-01-P00008 maintenance loop DIST-SLACK-004286 | RI-WARREN-FD-01-P00008 | DIST-FIBER-01092 | 239 ft | needs_field_verification |