Street-Path Continuity
ME-TAP136666-FD-01UNKNOWN133039-STR-0001 48F Patch Panel to DIST-POLE-0007590
- Route
- DIST-FIBER-00759
- Street path
- SYN-STREET-00759
- Fiber
- 24F
- Poles
- 10
- Scale
- 2,000
- Loss
- 2.33 dB
- 1ME-TAP136666-FD-01-P00001riser
- 2ME-TAP136666-FD-01-P00002distribution backbone
- 3ME-TAP136666-FD-01-P00003distribution backbone
- 4ME-TAP136666-FD-01-P00004distribution backbone
- 5ME-TAP136666-FD-01-P00005distribution backbone
- 6ME-TAP136666-FD-01-P00006distribution backbone
- 7ME-TAP136666-FD-01-P00007distribution backbone
- 8ME-TAP136666-FD-01-P00008distribution backbone
- 9ME-TAP136666-FD-01-P00009distribution backbone
- 10ME-TAP136666-FD-01-P00010fiber lateral
Services Carried
Telecom Backhaul on ME-TAP136666-FD-01Telecom Backhaul synthetic distribution telecom service familyproposednormalsynthetic2 strands1.37 dB
Distribution Automation on ME-TAP136666-FD-01Distribution Automation synthetic distribution telecom service familyproposedhighsynthetic2 strands1.37 dB
Voltage Regulator Backhaul on ME-TAP136666-FD-01Voltage Regulator Backhaul synthetic distribution telecom service familyproposednormalsynthetic2 strands1.49 dB
Feeder Automation on ME-TAP136666-FD-01Feeder Automation synthetic distribution telecom service familyproposedhighsynthetic2 strands1.60 dB
DERMS Field Telemetry on ME-TAP136666-FD-01DERMS Field Telemetry synthetic distribution telecom service familyproposednormalsynthetic2 strands1.71 dB
PMU Backhaul on ME-TAP136666-FD-01PMU Backhaul synthetic distribution telecom service familyproposedhighsynthetic2 strands1.95 dB
Protection Pilot on ME-TAP136666-FD-01Protection Pilot synthetic distribution telecom service familyproposedcriticalsynthetic2 strands2.07 dB
Recloser SCADA on ME-TAP136666-FD-01Recloser SCADA synthetic distribution telecom service familyproposedcriticalsynthetic2 strands2.07 dB
Splice and Slack Continuity
| Type | Node | Pole | Route | Slack | Status |
|---|
| riser terminal | ME-TAP136666-FD-01-P00001 riser terminal DIST-SPLICE-002398 | ME-TAP136666-FD-01-P00001 | DIST-FIBER-00759 | 242 ft | proposed |
| inline splice | ME-TAP136666-FD-01-P00006 inline splice DIST-SPLICE-002399 | ME-TAP136666-FD-01-P00006 | DIST-FIBER-00759 | 232 ft | proposed |
| inline splice | ME-TAP136666-FD-01-P00008 inline splice DIST-SPLICE-002400 | ME-TAP136666-FD-01-P00008 | DIST-FIBER-00759 | 145 ft | proposed |
| riser terminal | ME-TAP136666-FD-01-P00010 riser terminal DIST-SPLICE-002401 | ME-TAP136666-FD-01-P00010 | DIST-FIBER-00759 | 254 ft | proposed |
| riser storage | ME-TAP136666-FD-01-P00001 splice slack DIST-SLACK-002998 | ME-TAP136666-FD-01-P00001 | DIST-FIBER-00759 | 242 ft | proposed |
| splice slack | ME-TAP136666-FD-01-P00006 splice slack DIST-SLACK-002999 | ME-TAP136666-FD-01-P00006 | DIST-FIBER-00759 | 232 ft | proposed |
| splice slack | ME-TAP136666-FD-01-P00008 splice slack DIST-SLACK-003000 | ME-TAP136666-FD-01-P00008 | DIST-FIBER-00759 | 145 ft | proposed |
| riser storage | ME-TAP136666-FD-01-P00010 splice slack DIST-SLACK-003001 | ME-TAP136666-FD-01-P00010 | DIST-FIBER-00759 | 254 ft | proposed |
| maintenance loop | ME-TAP136666-FD-01-P00006 maintenance loop DIST-SLACK-003002 | ME-TAP136666-FD-01-P00006 | DIST-FIBER-00759 | 210 ft | in_service_synthetic |