Back to map dashboardDistribution Pole Fiber Continuity
CT-CONGRESS-ST-FD-01 synthetic telecom fiber / CT-CONGRESS-ST-FD-01 synthetic telecom fiber
!Synthetic distribution continuity only. Do not use for operations, dispatch, restoration, SCADA, protection, or CEII analysis.
Utility ownerUnited Illuminating Company
StateCT
Fiber routeDIST-FIBER-00037
Fiber count24F
Display poles10
Scale model2,000
Splice points2
Slack loops3
Slack storage643 ft
Assignments8
Route miles3.98
Estimated loss2.14 dB
Continuitycomplete synthetic
Statusin service synthetic
Street-Path Continuity
CT-CONGRESS-ST-FD-01PIPER-STR-0001 24F Patch Panel to DIST-POLE-0000370
- Route
- DIST-FIBER-00037
- Street path
- SYN-STREET-00037
- Fiber
- 24F
- Poles
- 10
- Scale
- 2,000
- Loss
- 2.14 dB
- 1CT-CONGRESS-ST-FD-01-P00001riser
- 2CT-CONGRESS-ST-FD-01-P00002distribution backbone
- 3CT-CONGRESS-ST-FD-01-P00003distribution backbone
- 4CT-CONGRESS-ST-FD-01-P00004distribution backbone
- 5CT-CONGRESS-ST-FD-01-P00005distribution backbone
- 6CT-CONGRESS-ST-FD-01-P00006distribution backbone
- 7CT-CONGRESS-ST-FD-01-P00007distribution backbone
- 8CT-CONGRESS-ST-FD-01-P00008distribution backbone
- 9CT-CONGRESS-ST-FD-01-P00009distribution backbone
- 10CT-CONGRESS-ST-FD-01-P00010fiber lateral
Services Carried
Telecom Backhaul on CT-CONGRESS-ST-FD-01Telecom Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.24 dB
Distribution Automation on CT-CONGRESS-ST-FD-01Distribution Automation synthetic distribution telecom service familyactive synthetichighsynthetic2 strands1.35 dB
PTP Timing Extension on CT-CONGRESS-ST-FD-01PTP Timing Extension synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.44 dB
Wireless Backhaul Handoff on CT-CONGRESS-ST-FD-01Wireless Backhaul Handoff synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.44 dB
Spare on CT-CONGRESS-ST-FD-01Spare synthetic distribution telecom service familyreservedlowsynthetic2 strands1.66 dB
Voltage Regulator Backhaul on CT-CONGRESS-ST-FD-01Voltage Regulator Backhaul synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.76 dB
DERMS Field Telemetry on CT-CONGRESS-ST-FD-01DERMS Field Telemetry synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.76 dB
Voice Operations on CT-CONGRESS-ST-FD-01Voice Operations synthetic distribution telecom service familyactive syntheticnormalsynthetic2 strands1.98 dB
Splice and Slack Continuity
| Type | Node | Pole | Route | Slack | Status |
|---|
| riser terminal | CT-CONGRESS-ST-FD-01-P00001 riser terminal DIST-SPLICE-000115 | CT-CONGRESS-ST-FD-01-P00001 | DIST-FIBER-00037 | 204 ft | in_service_synthetic |
| riser terminal | CT-CONGRESS-ST-FD-01-P00010 riser terminal DIST-SPLICE-000116 | CT-CONGRESS-ST-FD-01-P00010 | DIST-FIBER-00037 | 200 ft | in_service_synthetic |
| riser storage | CT-CONGRESS-ST-FD-01-P00001 splice slack DIST-SLACK-000142 | CT-CONGRESS-ST-FD-01-P00001 | DIST-FIBER-00037 | 204 ft | in_service_synthetic |
| riser storage | CT-CONGRESS-ST-FD-01-P00010 splice slack DIST-SLACK-000143 | CT-CONGRESS-ST-FD-01-P00010 | DIST-FIBER-00037 | 200 ft | in_service_synthetic |
| maintenance loop | CT-CONGRESS-ST-FD-01-P00005 maintenance loop DIST-SLACK-000144 | CT-CONGRESS-ST-FD-01-P00005 | DIST-FIBER-00037 | 239 ft | in_service_synthetic |